instruction
stringlengths 150
244
| output
stringclasses 28
values |
---|---|
Consider the scope on 'VIE' in the functional location GIR/FPSOT/CRS/AIR /DS831C, the given unit name KX830C-AIR/ WATER SEPARATOR (V), the corresponding item class discipline would be | Pressure Vessel (VIE) |
Consider the scope on TANKER MOORING HAWSER SB/WEAR MEASUR in the functional location GIR/BUOY /OIL/LOAD /MOORING HAWSER SB the given unit name of BUOY MOORING HAWSER STARBOARD the corresponding item class discipline would be | FU Items |
Consider the scope on Pre-Pop test, overhaul & recalibration in the functional location CLV/FPSOT/GAS/COMP /TO-PSV-31503A2 the given unit name of HP3 COMP. SCRUBBER A PRESS. SAF. VLV A2 the corresponding item class discipline would be | Pressure Safety Device |
Consider the scope on UTC + VIE in the functional location DAL/FPSOT/OIL/SEP /IPN-_NW-0633-16-C513 the given unit name of LINE GROUP,OIL DESALT,WATER,CS,IPN the corresponding item class discipline would be | Piping |
Consider the scope on VIE in the functional location CLV/FPSOH/COF/INERT/IPN-_HG-HU74-22-B03 the given unit name of Hydrocarbon gas piping group the corresponding item class discipline would be | Piping |
Consider the scope on VIE in the functional location DAL/FPSOT/COF/FG /IPN-_DF-0637-90-D513 the given unit name of LINE GROUP,CLOSED DRAIN,DRAIN,CS,IPN the corresponding item class discipline would be | Piping |
Consider the scope on PSD Replacement in the functional location CLV/FPSOT/EXT/TRANS/TO-PSV-0762B the given unit name of BF HPU PSV SUPPLY PUMP B OUTLET the corresponding item class discipline would be | Pressure Safety Device |
Consider the scope on SCD + VIE in the functional location CLV/FPSOT/WAT/WFLT /IPN-_SW-TO51-14-D71 the given unit name of Sea water piping group the corresponding item class discipline would be | Piping |
Consider the scope on VIE in the functional location GIR/FPSOT/GAS/FLARE/IPN-FS-_436-03-B600 the given unit name of PIPING GROUP GAS FLARE the corresponding item class discipline would be | Piping |
Consider the scope on 'Pre-pop test & Recalibration' in the functional location DAL/FPSOT/EXT/EWELL/6-PSV-30411L, the given unit name PRESSURE SAFETY VALVE, PIG LINE TO FLARE, the corresponding item class discipline would be | Pressure Safety Device |
Consider the scope on GIR/41-PSV-7533A-Replace/Scrap in the functional location GIR/FPSOT/WAT/WINJ /41-PSV7533A the given unit name of CA704A SOUPAPE DE SECURITE the corresponding item class discipline would be | Pressure Safety Device |
Consider the scope on 'VIE' in the functional location DAL/FPSOT/WAT/WDEOX/IP_GVI_DS_LINES, the given unit name DS GROUP OF LINES FOR GVI, the corresponding item class discipline would be | Piping |
Consider the scope on 'NDE' in the functional location DAL/FPSOT/HSG/STRUC/TOPSIDE-P31-PRM-STR, the given unit name Fourth Topside P31 Structure Inspection, the corresponding item class discipline would be | Structure |
Consider the scope on VIE in the functional location DAL/FPSOT/OIL/DRAIN/IPN-_DF-0637-08-F513 the given unit name of LINE GROUP,CLOSED DRAIN,DRAIN,CS,IPN the corresponding item class discipline would be | Piping |
Consider the scope on 'GIR/41-PSV2-6104-Révision' in the functional location GIR/FPSOT/GAS/DEHYD/41-PSV2-6104, the given unit name DS601 SOUPAPE DE SECURITE, the corresponding item class discipline would be | Pressure Safety Device |
Consider the scope on 'Overhaul' in the functional location PAZ/FPSOT/OIL/STAB /TO-PSV4-21044B, the given unit name TO LP FLARE PRESSURE SAFETY VALVE, the corresponding item class discipline would be | Pressure Safety Device |
Consider the scope on VIE in the functional location DAL/FPSOT/COF/INWAT/IPN-_GH-0641-06-B513 the given unit name of LINE GROUP,H2O TREAT,OIL,CS,IPN the corresponding item class discipline would be | Piping |
Consider the scope on VIE in the functional location DAL/FPSOT/GAS/COMP /IPN-_NG-0652-32-B513 the given unit name of LINE GROUP,HP GAS,GAS,CS,IPN the corresponding item class discipline would be | Piping |
Consider the scope on 'VIE' in the functional location CLV/FPSOH/HSG/UPWAT/HU-VZ-8532A, the given unit name of BRACKISH WATER MEMBRANE VESSEL, the corresponding item class discipline would be | Pressure Vessel (VIE) |
Consider the scope on SCD + VIE in the functional location GIR/FPSOT/COF/FG /IPC-FG-_470-02-C670 the given unit name of PIPING GROUP FUEL GAS the corresponding item class discipline would be | Piping |
Consider the scope on VII in the functional location PAZ/FPSOH/OIL/OWAT /HU-TZ-2754 the given unit name of FW MAKER ROOM AFT BILGE WELL the corresponding item class discipline would be | Non Structural Tank |
Consider the scope on 'UTC + VIE' in the functional location PAZ/FPSOT/OIL/STAB /IPC-_HL-TO21-05-D03, the given unit name Hydrocarbon G/L piping group, the corresponding item class discipline would be | Piping |
Consider the scope on Major Intrus.insp_TO-FA-45104 FL.ARRAST in the functional location GIR/FPSOT/GAS/COMP /TO-FA-45104 the given unit name of FLAME ARRESTOR,VENT TCA 4-AV-4-5104-B511 the corresponding item class discipline would be | Flame Arrestor |
Consider the scope on VIE in the functional location PAZ/FPSOT/OIL/DRAIN/IPN-_CD-TO28-14-B49 the given unit name of Closed drain piping group the corresponding item class discipline would be | Piping |
Consider the scope on 'VIE' in the functional location DAL/FPSOT/COF/CHEM /IPN-_AM-0619-12-G580, the given unit name LINE GROUP,METHANOL,METHANOL,SS,IPN, the corresponding item class discipline would be | Piping |
Consider the scope on 'VIE' in the functional location DAL/FPSOT/COF/COOLW/6-DA-1500, the given unit name COOLING MEDIUM EXPANSION DRUM, the corresponding item class discipline would be | Pressure Vessel (VIE) |
Consider the scope on VIE in the functional location DAL/FPSOT/OIL/SEP /IPN-_TW-0633-01-C670 the given unit name of LINE GROUP,OIL DESALT,WATER,SS,IPN the corresponding item class discipline would be | Piping |
Consider the scope on VIE in the functional location PAZ/FPSOH/COF/FO /IPN-_DO-HU71-03-_49 the given unit name of Diesel oil piping group the corresponding item class discipline would be | Piping |
Consider the scope on 'UTC + VIE' in the functional location PAZ/FPSOT/OIL/TRANS/IPN-_HC-TO23-08-J03P, the given unit name Glycol (TEG) piping group, the corresponding item class discipline would be | Piping |
Consider the scope on 'Visual inspection of tertiary structure' in the functional location PAZ/FPSOT/HSG/STRUC/R7, the given unit name R7 Structural Module, the corresponding item class discipline would be | Structure |
Consider the scope on Hawser hook weaer measurement in the functional location CLV/BUOY /HSG/STRUC/OB-JL-8660A the given unit name of BUOY QUICK RELEASE HOOK A the corresponding item class discipline would be | FU Items |
Consider the scope on 'Overhaul' in the functional location PAZ/FPSOT/WAT/WFLT /TO-PSV2-51002, the given unit name ESSENTIAL SW COARSE FILTRAT PSV, the corresponding item class discipline would be | Pressure Safety Device |
Consider the scope on VII in the functional location PAZ/FPSOT/OIL/OWAT /TO-V_-2713 the given unit name of P.W SURGE DRUM the corresponding item class discipline would be | Pressure Vessel (VII) |
Consider the scope on UTC + VIE in the functional location PAZ/FPSOH/OIL/STORE/IPN-_HL-HU24-12-B03 the given unit name of Hydrocarbon liquid piping group the corresponding item class discipline would be | Piping |
Consider the scope on 5-TA-8145/FU Tank Class Survey in the functional location DAL/FPSOH/HSG/STRUC/5-TA-8145 the given unit name of NO.4 WATER BALLAST TANK (S) the corresponding item class discipline would be | FU Items |
Consider the scope on 'Pre-pop test & Recalibration' in the functional location DAL/FPSOT/GAS/COMP /6-PSV-52538A, the given unit name PRES/ SAFETY VALVE, FUEL OIL RETURN, the corresponding item class discipline would be | Pressure Safety Device |
Consider the scope on 'COR - APT_P_CP Measurement' in the functional location CLV/FPSOH/HSG/STRUC/HU-TR-8631D, the given unit name of PORT WING BALLAST BUFFER TANK D, the corresponding item class discipline would be | Corrosion Monitoring |
Consider the scope on VIE in the functional location DAL/FPSOT/GAS/DEHYD/6-DS-5500 the given unit name of TEG FLASH DRUM the corresponding item class discipline would be | Pressure Vessel (VIE) |
Consider the scope on VIE in the functional location PAZ/FPSOT/OIL/DRAIN/IPN-_RW-TO28-01-B03 the given unit name of Desalinated water piping group the corresponding item class discipline would be | Piping |
Consider the scope on VIE + NDT in the functional location CLV/FPSOH/COF/INERT/IPN-_HG-HU74-09-B03 the given unit name of Hydrocarbon gas piping group the corresponding item class discipline would be | Piping |
Consider the scope on 'UTC + VIE' in the functional location GIR/FPSOT/COF/CHEM /IPN-AM-_475-01-B511, the given unit name PIPING GROUP CHEMICAL INJECTION, the corresponding item class discipline would be | Piping |
Consider the scope on 'Major Non Intrusive Insp TA861C' in the functional location GIR/FPSOT/COF/CHEM /TA861C, the given unit name BLEND SUBSEA TANK (T), the corresponding item class discipline would be | Non Structural Tank |
Consider the scope on 'UTC + VIE' in the functional location PAZ/FPSOT/OIL/DRAIN/IPN-_CD-TO28-06-D03, the given unit name Hydrocarbon liquid piping group, the corresponding item class discipline would be | Piping |
Consider the scope on 'VIE' in the functional location DAL/FPSOT/EXT/EWELL/IPN-_NH-0630-35-F710, the given unit name LINE GROUP,OIL RAW,OIL,DUPLEX,IPN, the corresponding item class discipline would be | Piping |
Consider the scope on 'VIE' in the functional location PAZ/FPSOT/WAT/WATLF/IPN-_SW-TO50-09-B92, the given unit name Hydrocarbon G/L piping group, the corresponding item class discipline would be | Piping |
Consider the scope on 'NDE' in the functional location DAL/FPSOT/HSG/STRUC/TOPSIDE-P61-PRM-STR, the given unit name MODULE P61,TOPSIDE PRIMARY STRUCTURE, the corresponding item class discipline would be | Structure |
Consider the scope on VIE in the functional location CLV/FPSOH/HSG/UPWAT/IPN-_BW-HU85-02-_49 the given unit name of Fresh water piping group the corresponding item class discipline would be | Piping |
Consider the scope on 'UTC + VIE' in the functional location CLV/FPSOT/OIL/DRAIN/IPN-_CD-TO28-21-H21N, the given unit name of Closed drain piping group, the corresponding item class discipline would be | Piping |
Consider the scope on FI Visual Inspection of complete struct. in the functional location CLV/FPSOT/HSG/STRUC/M116 the given unit name of M116 Structural Module GLYCOL GENERATION the corresponding item class discipline would be | Structure |
Consider the scope on TA042/COR CP Measurement in the functional location GIR/FPSOH/HSG/STRUC/TA042 the given unit name of AFT PEAK WBT STARBOARD (T) the corresponding item class discipline would be | Corrosion Monitoring |
Consider the scope on UTC + VIE in the functional location PAZ/FPSOT/COF/COOLW/IPN-_CW-TO76-03-B01 the given unit name of Cooling water piping group the corresponding item class discipline would be | Piping |
Consider the scope on GIR/42-PSV-7606-Echange Standard in the functional location GIR/FPSOH/HSG/STRUC/42-PSV7606 the given unit name of GX925 SOUPAPE DE SECURITE the corresponding item class discipline would be | Pressure Safety Device |
Consider the scope on VIE in the functional location PAZ/FPSOT/EXT/EWELL/TO-TZ-9141 the given unit name of HPU RETURN OIL TANK the corresponding item class discipline would be | Non Structural Tank |
Consider the scope on CLASS PSV-Overhaul in the functional location CLV/FPSOT/COF/CHEM /TO-PSV-75401B the given unit name of HU-TR-7550AB PRESS. OUTLET SFTY VALVE B the corresponding item class discipline would be | Pressure Safety Device |
Consider the scope on 'CLOV Lifting coding/energ campaign' in the functional location CLV/FPSOH/COF/LIFT, the given unit name of Lifting equipment, the corresponding item class discipline would be | Campaign |
Consider the scope on VII in the functional location PAZ/FPSOT/ELE/PWG /TO-VZ-6035E the given unit name of MINERAL OIL VAPOR SERPARATOR the corresponding item class discipline would be | Pressure Vessel (VII) |
Consider the scope on 'VIE' in the functional location GIR/FPSOT/HSG/UPWAT/IPN-TW-_485-07-B630, the given unit name PIPING GROUP SOFT WATER, the corresponding item class discipline would be | Piping |
Consider the scope on Major Intrus.insp_TO-FA-45206 FL.ARRAST in the functional location GIR/FPSOT/GAS/COMP /TO-FA-45206 the given unit name of FLAME ARRESTOR,VENT TCB 3-AV-4-5206-B511 the corresponding item class discipline would be | Flame Arrestor |
Consider the scope on 'CLASS PSV-GIR/41-PSV-0150-Révision' in the functional location GIR/FPSOT/OIL/STORE/41-PSV0150, the given unit name TA015 SOUPAPE DE SECURITE, the corresponding item class discipline would be | Pressure Safety Device |
Consider the scope on 5-TA-8120/FU Tank Class Survey in the functional location DAL/FPSOH/HSG/STRUC/5-TA-8120 the given unit name of NO.2 WATER BALLAST TANK (P) the corresponding item class discipline would be | FU Items |
Consider the scope on 'GIR/PSV-4531-REVISION' in the functional location GIR/FPSOT/OIL/OWAT /41-PSV4531, the given unit name SOUPAPE DE SURETE, ENTREE POMPES GAVAGE, the corresponding item class discipline would be | Pressure Safety Device |
Consider the scope on DAL/FPSO mooring chains inspection in the functional location DAL/FPSOH/HSG/STRUC/FPSO-TOPSIDE-MOORING the given unit name of FPSO TOPSIDE MOORING the corresponding item class discipline would be | FU Items |
Consider the scope on 'VIE' in the functional location DAL/FPSOT/GAS/COMP /IPN-_NG-0656-09-G600, the given unit name LINE GROUP,GAS LIFT,GAS,SS,IPN, the corresponding item class discipline would be | Piping |
Consider the scope on 'COR - WBT7S - CP Measurement' in the functional location DAL/FPSOH/HSG/STRUC/5-TA-8175, the given unit name NO/7 WATER BALLAST TANK (S), the corresponding item class discipline would be | Corrosion Monitoring |
Consider the scope on GIR/41-PSV5-3004-RŽvision in the functional location GIR/FPSOT/OIL/SEP /41-PSV5-3004 the given unit name of DS301 SOUPAPE DE SECURITE the corresponding item class discipline would be | Pressure Safety Device |
Consider the scope on 'UTC + VIE' in the functional location CLV/FPSOT/OIL/SEP /IPN-_HG-TO20-37-B03, the given unit name of Hydrocarbon gas piping group, the corresponding item class discipline would be | Piping |
Consider the scope on SCD + VIE in the functional location PAZ/FPSOT/GAS/TRANS/IPN-_HG-TO34-06-H49P the given unit name of Hydrocarbon gas piping group the corresponding item class discipline would be | Piping |
Consider the scope on 'CLASS PSV-Overhaul' in the functional location PAZ/FPSOT/COF/CHEM /TO-PVSV-752549, the given unit name PRESSURE VACUUM SAFETY VALVE, the corresponding item class discipline would be | Pressure Safety Device |
Consider the scope on 'GIR/BUOY COMPART_INTRUSIVE' in the functional location GIR/BUOY /HSG/STRUC/COMP C, the given unit name GIRASSOL BUOY-COMPARTMENT C, the corresponding item class discipline would be | FU Items |
Consider the scope on VIE in the functional location PAZ/FPSOT/GAS/COMP /TO-V_-3160 the given unit name of HHP COMPRESSOR SUCTION SCRUBBER the corresponding item class discipline would be | Pressure Vessel (VIE) |
Consider the scope on M2-Visual inspection of complete struct in the functional location GIR/FPSOT/HSG/STRUC/MOD M2 the given unit name of STRUCTURAL MODULE M2 the corresponding item class discipline would be | Structure |
Consider the scope on 'VIE' in the functional location PAZ/FPSOT/COF/CHEM /IPN-_ME-TO75-03-_23, the given unit name Hydrocarbon gas piping group, the corresponding item class discipline would be | Piping |
Consider the scope on VII in the functional location PAZ/FPSOT/WAT/WATLF/TO-TZ-5012B the given unit name of MAIN PUMP TANK B the corresponding item class discipline would be | Non Structural Tank |
Consider the scope on 'Pre-pop test & Recalibration' in the functional location DAL/FPSOT/GAS/COMP /6-PSE-21115, the given unit name BURSTING DISC, TO HP FLARE, the corresponding item class discipline would be | Pressure Safety Device |
Consider the scope on 'SCD + VIE' in the functional location PAZ/FPSOT/GAS/DEHYD/IPN-_HG-TO30-05-F01, the given unit name Hydrocarbon gas piping group, the corresponding item class discipline would be | Piping |
Consider the scope on VIE in the functional location DAL/FPSOT/COF/FG /IPN-_DF-0637-51-D513 the given unit name of LINE GROUP,CLOSED DRAIN,DRAIN,CS,IPN the corresponding item class discipline would be | Piping |
Consider the scope on 'VIE' in the functional location GIR/FPSOT/CRS/AIR /DS830C, the given unit name KX830C-AIR/ WATER SEPARATOR (V), the corresponding item class discipline would be | Pressure Vessel (VIE) |
Consider the scope on CLV/TO-V-35690 FLAME ARRESTOR in the functional location CLV/FPSOH/OIL/STORE/TO-V-35690 the given unit name of FLAME ARRESTOR, VENT COT_7P, HU-TR-2417 the corresponding item class discipline would be | Flame Arrestor |
Consider the scope on 'GVI' in the functional location DAL/FPSOH/HSG/ACCOM/5-TA-9382, the given unit name CONTACT TANK, the corresponding item class discipline would be | FU Items |
Consider the scope on Replace/Scrap 6-PSV-77570A in the functional location DAL/FPSOT/WAT/WINJ /6-PSV-77570A the given unit name of PRES. SAF. VALVE, ANTI SCALE PUMP OUTLET the corresponding item class discipline would be | Pressure Safety Device |
Consider the scope on 'Remote Int. Inspection-TO-FL-3620' in the functional location PAZ/FPSOT/GAS/FLARE/TO-FL-3620, the given unit name LP FLARE TIP, the corresponding item class discipline would be | Flare TIP |
Consider the scope on 'VIE' in the functional location DAL/FPSOT/EXT/EWELL/IPN-_NH-0630-06-F710, the given unit name LINE GROUP,OIL RAW,OIL,DUPLEX,IPN, the corresponding item class discipline would be | Piping |
Consider the scope on VIE in the functional location CLV/FPSOH/COF/CHEM /IPN-_LD-HU75-04-_03 the given unit name of Dosage hydrate inhibitor piping group the corresponding item class discipline would be | Piping |
Consider the scope on VIE in the functional location CLV/FPSOT/HSG/UPWAT/IPN-_DW-TO85-01-B49 the given unit name of Drinking water piping group the corresponding item class discipline would be | Piping |
Consider the scope on 'GVI' in the functional location DAL/BUOY /HSG/STRUC/COMP 13, the given unit name BUOY TANK COMPARTMENT, the corresponding item class discipline would be | FU Items |
Consider the scope on Inspection - GIR - HELIDECK in the functional location GIR/FPSOT/HSG/STRUC/HELIDECK the given unit name of HELIDECK DU FPSO GIRASSOL the corresponding item class discipline would be | FU Items |
Consider the scope on 'VIE' in the functional location GIR/FPSOT/GAS/FLARE/41-DS-SDV2086B, the given unit name CAPACITE AIR, CONDENSATS FILTRE ENTREE, the corresponding item class discipline would be | Pressure Vessel (VIE) |
Consider the scope on Overhaul Inspection 6-PSV1-15014 in the functional location DAL/FPSOT/COF/COOLW/6-PSV1-15014 the given unit name of PRES. SAF. VALVE, EXPANSION DRUM OUTLET the corresponding item class discipline would be | Pressure Safety Device |
Consider the scope on UTC + VIE in the functional location PAZ/FPSOT/OIL/STAB /IPN-_HL-TO21-07-B03 the given unit name of Hydrocarbon liquid piping group the corresponding item class discipline would be | Piping |
Consider the scope on PAZ/BUOY COMPART_INTRUSIVE in the functional location PAZ/BUOY /HSG/STRUC/COMP 14 the given unit name of PAZ STRUTURAL COMPARTMENT the corresponding item class discipline would be | FU Items |
Consider the scope on TA043/COR CP Measurement in the functional location GIR/FPSOH/HSG/STRUC/TA043 the given unit name of WATER BALLAST 6 PORTSIDE (T) the corresponding item class discipline would be | Corrosion Monitoring |
Consider the scope on 'GIR/41-PSV1-5107A-Révision' in the functional location GIR/FPSOT/GAS/COMP /41-PSV1-5107A, the given unit name KY512A SOUPAPE SECURITE REFOUL., the corresponding item class discipline would be | Pressure Safety Device |
Consider the scope on 'UTC + VIE' in the functional location PAZ/FPSOH/OIL/STORE/IPN-_HL-HU24-26-B03, the given unit name Hot water piping group, the corresponding item class discipline would be | Piping |
Consider the scope on 'VIE' in the functional location DAL/FPSOT/EXT/EWELL/IPN-_NH-0630-74-F513, the given unit name LINE GROUP,OIL RAW,OIL,CS,IPN, the corresponding item class discipline would be | Piping |
Consider the scope on VIE in the functional location GIR/FPSOT/COF/HEATL/EC950C the given unit name of WHRUC-HEATER FOR HOT WATER (E) the corresponding item class discipline would be | Pressure Vessel (VIE) |
Consider the scope on 'VIE' in the functional location DAL/FPSOT/GAS/COMP /IPN-_NG-0656-17-G800, the given unit name LINE GROUP,GAS LIFT,GAS,INCONEL,IPN, the corresponding item class discipline would be | Piping |
Consider the scope on VIE in the functional location PAZ/FPSOH/HSG/UPWAT/IPN-_SW-HU85-02-_92 the given unit name of Sea water piping group the corresponding item class discipline would be | Piping |
Consider the scope on PSD Replacement in the functional location CLV/FPSOH/CRS/AIR /HU-PSV1-0766V the given unit name of TANK WT_P VALVE CONTROL PANEL V PSV the corresponding item class discipline would be | Pressure Safety Device |
Consider the scope on 'Major Non Intrusive Insp TA753' in the functional location GIR/FPSOT/HSG/UPWAT/TA753, the given unit name CIP TANK (T), the corresponding item class discipline would be | Non Structural Tank |
Consider the scope on 'VIE' in the functional location PAZ/FPSOT/OIL/STAB /IPN-_HL-TO21-03-B03, the given unit name Produced water piping group, the corresponding item class discipline would be | Piping |
Subsets and Splits
No community queries yet
The top public SQL queries from the community will appear here once available.